33 kV Current Transformer (CG India)
CGCT33(25-50)CGCT33(50-100)CGCT33(100-200)CGCT33(200-400)CGCT33(400-800)CGCT33(150-300)CGCT33(300-600)CGCT33(75-150)CGCT33(1000-2000)Special Features:
- Self cooled
- Hermetically sealed and suitable for operating in the tropical conditions with maximum ambient temperature up to 50’C
- Suitable for use in the areas subject to heavy lightning storms and highly polluted conditions.
-
33 kV Indoor Gas Insulated switchgear (CG India)
36 GIS Control Panel
Special Features:
- Fully type tested
- Compact design & reduced space requirement
- Sealed for life
- High degree of reliability and safety
- Virtually maintenance free equipment
- Easy future extensibility of the network through flexibke plug in connectors.
- Ring type current Transformers
- Touch proof cable connectors & bus bar
-
33 kV Lightning Arrester (CG India)
ZLAX
Special Features:
- Highly nonlinear ceramic resistors made essentially of zinc oxide
- Unique doughnut construction of ZnO elements offer high energy capability, provide uniform density and temperature distribution.
- Shutter proof performance
- Robust construction of arresters
- Extremely high non-linearity of ZnO elements
- Positive locking of Zinc Oxide elements
-
33 kV Metering Panel (CG India)
33KVMTP25-5033KVMTP50-100-M33KVMTP100-200-M33KVMTP100-20033KVMTP200-400Special Features:
- Which matures various ampere, kwh, voltage
-
33 kV Outdoor Gas Circuit Breaker (CG India)
33-OD-SFG-CC33-OD-SFG-TC33-OD-SFG-TC-110Special Features:
- IEC 62271Â 100
- Spring – spring mechanism type
- Vertical porcelain units containing puffer type interrupter
- Spring – spring operating mechanism and control equipment in a single housing
- Base frame and support columns.
-
33 kV Voltage Transformer (CG India)
CGVT33
Special Features:
- Bottom tank is made of high quality sheet steel and shaped to conform active part og the VT.
- Lifting Lugs and mounting holes are provided on the tank.
-
33KV-OC
33 KV-OC
Conductor : Compacted round stranded hard drawn aluminium wires
: Single-core : Size 35 mm² up to 185 mm²Insulation : Black Cross-linked polyethylene (XLPE) Core indentification : Color : Black Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 33,000 VoltsTesting voltage : 17,000 Volts Reference standard : ICEA S-66-524, ICEA S-93-639 -
6/10(12) KV-CV
6/10(12) KV-CVÂ Â Â Â Â Â Â : Compact and round stranded annealed copper
                         : 16 mm2 up to 1000 mm2 (Single Core)
                         : 16 mm2 up to 400 mm2 (3 Cores)
                          : Cross-linked Polyethylene (XLPE)
                          : Black Polyvinyl Chloride (PVC/ST2)
                          : Copper Tape (Sheath)
                          : Maximum conductor temperature 90 Degree C
                          : Circuit voltage not exceeding 12000 V
Insulation shield layer : Semi-conducting covering remove at splices or terminals
                 : 21000 V (Testing Voltage) -
60227 IEC 01 THW
Non-Sheathed Cables for Fixed Wiring
Building wiring for installation on insulator or in raceway, dry location.
-
60227 IEC 02 THW (F)
Flexible CablesÂ
60227 IEC 02 THW (F) Â Â Â Â :Â Flexible annealed copper wire
                    : 1.5 mm2 up to 240 mm2
                    : Polyvinyl Chloride (PVC/C)
                    : Any Color (Single Core)
                    : Maximum conductor temperature 70 °C
                    : Circuit Voltage not exceeding 450/750 V
                    : 2500 V (Testing Voltage)
-
60227 IEC 10 NYY
Sheathed Cables for Fixed Wiring
60227 IEC 10 NYYÂ Â Â Â Â Â Â Â Â Â Â Â :Â Solid and stranded annealed copper
                                       : 1.5 mm2 up to 10 mm2 (Solid)
                                       : 1.5 mm2 up to 35 mm2 (Stranded)
                                       : Polyvinyl chloride (PVC/C)
                                       : 2 Cores to 5 Cores
                                       : Black Polyvinyl Chloride (Inner Sheath) (PVC)
                                       : Black Polyvinyl Chloride (Outer Sheath) (PVC/ST4)
                                       : Maximum conductor temperature 70 °C
                                       : Circuit Voltage not exceeding 300/500 V
                                       : 2000 V (Testing Voltage)
-
60227 IEC 53 VCT
Flexible Cables
For household appliances, electrical equipment and electrical illumination.