Showing 13–24 of 26 results
-
CVV or CVV-S
For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.
-
FD 0.6/1 KV-CV
FD 0.6/1 KV-CV Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â : Concentric Stranded and compacted round annealed copper
                     : 1.5 mm2 up to 1000 mm2 (Single Core)
                     : 1.5 mm2 up to 400 mm2 (Multi Cores)
                     : Single core to 4 cores
                     : Cross-linked Polyethylene (XLPE)
                     : Black flame retardant polyvinyl chloride (PVC/ST2)
                     : Maximum conductor temperature 90 °C
                     : Circuit voltage not exceeding 1200 V
                     : 3500 V (Testing Voltage)
-
FD 0.6/1 KV-CV-SWA
FD 0.6/1 KV-CV-SWAÂ Â Â Â : Concentric stranded and compact stranded annealed copper
: 1.5mm2 up to 400 mm2
: 2 cores to 4 cores
: Cross-linked Polyethylene (XLPE)
: Black Polyvinyl Chloride (PVC) (Inner Sheath)
                   : Black flame retardant polyvinyl chloride                                     (PVC/ST2) (Outer Sheath)
                 : Galvanized Steel Wires (Armor)
                   : Maximum conductor temperature 90 °C
              : Circuit voltage not exceeding 1200 V
: 3500 V (Testing Voltage) -
FD-0.6/1KV-AL-CV
FD-0.6/1KV-AL-CV
Conductor : Concentric stranded and hard drawn alminium
: Single-core : Size 10 mm² up to 500 mm²
: Multi-core : Size 10 mm² up to 400 mm²Insulation : Cross-linked Polyethylene (XLPE) Core identification : Single-core : Natural (Translucent)
: 2 Core : Blue and Brown
: 3 Core : Brown, Black and Grey
: 4 Core : Blue, Brown, Black and Grey
: Other colors are available on customer requestSheath : Black Flame retardant polyvinyl chloride (PVC/ST2) Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 1,200 VoltsRated voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1 -
FD-0.6/1KV-AL-CV-SWA
FD-0.6/1 KV-CV-SWA
Conductor : Concentric stranded and hard drawn aluminium
: Size 10 mm² up to 400 mm² (Multi Core)Insulation : Cross-linked Polyethylene (XLPE) Core identification : Compound color or color tape
: 2 Core : Blue and Brown
: 3 Core : Brown, Black and Grey
: 4 Core : Blue, Brown, Black and Grey
: Other colors are available on customer requestArmor : Galvanized steel wires Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2) Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 1,200 Volts
: Rated voltage (U0Â /U) 0.6/1 KV
: 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
: IEC 60332-3-24 (Cat.C)
-
FDLH-0.6/1KV-CE
FDLH-0.6/1KV-CE
Conductor : Non-compacted and compacted round annealed copper
Single-core Size 1.5 mm² up to 1000 mm²Insulation : Cross-Linked polyetylene (XLPE) Core identification : Single-crosss : Natural (Translucent)
: 2 Cores : Blue, Brown
: 3 Cores : Brown, Black, Gray
: 4 Cores : Blue, Brown, Black, GrayShield : Black Low smoke and zero halogen flame retardant polylefin (ST8) Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 1,200 VoltsRelated Voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502, IEC 60228, IEC 60332-1,
 IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2
-
FRLH-IE
FRLH-IE
Conductor : Non-compacted and compacted round annealed copper
Size 1.5 mm² up to 630 mm²Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen Core identification : Single-crosss : Black or Orange Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 450/750 VoltsRelated Voltage : 45 Volts between Line-to-Earth
: 75 Volts between Line-to-LineTesting voltage : 2,500 Volts Reference standard : BS EN 50525-3-41, BS EN 60228, BS EN 60332-1,
 BS EN 60332-3-24 (Cat.C), BS EN 50267-2-2, BS EN 61034-2
-
FS/LH-0.6/1KV-XLPE(C)
FS/LH-0.6/1KV-XLPE (C)
Conductor : Non-compacted and compacted round annealed copper
Single-core Size 1.5 mm² up to 630 mm²Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen Core identification : Signle-cores: Blank or Orange Fire barier tape : Mica tape Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 600/1000 VoltsRelated Voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, BS 6387 (Cat.CWZ),
 IEC 60332-1, IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2
-
HWA OR THWA-C
THWA OR THWA-CÂ Â Â : Solid and stranded hard drawn aluminium wires (THWA)
                        : Compact stranded hard drawn aluminium wires (THWA-C)
                         : 10 mm2 up to 500 mm2
                          : Black Polyvinyl Chloride (PVC)
                         : Maximum conductor temperature 70 °C
                         : Circuit voltage not exceeding 750 VÂ
                         : 2500 V (Testing Voltage)