Showing 13–24 of 26 results

  • AAC

    AAC  : Concentric stranded hard drawn aluminium wires
    (All Aluminium Conductor)     : 16 mm2 up to 1000 mm2
                                              : outermost layer Z

    Read more
  • ACSR

    ACSR            : Hard drawn aluminium wire
                        : 16 mm2 up to 680 mm2 
                        : Galvanized steel (Zinc coated), solid and concentric stranded, 2.5 mm2 up to 85 mm2
                        : outermost layer Z

    Read more
  • CVV or CVV-S

    For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.

    Read more
  • FD 0.6/1 KV-CV

    FD 0.6/1 KV-CV                  : Concentric Stranded and compacted round annealed copper

                                             : 1.5 mm2 up to 1000 mm2 (Single Core)

                                             : 1.5 mm2 up to 400 mm2 (Multi Cores)

                                             : Single core to 4 cores

                                             : Cross-linked Polyethylene (XLPE)

                                             : Black flame retardant polyvinyl chloride (PVC/ST2)

                                             : Maximum conductor temperature 90 °C

                                             : Circuit voltage not exceeding 1200 V

                                             : 3500 V (Testing Voltage)

    Read more
  • FD 0.6/1 KV-CV-SWA

    FD 0.6/1 KV-CV-SWA     : Concentric stranded and compact stranded annealed copper
    : 1.5mm2 up to 400 mm2
    : 2 cores to 4 cores
    : Cross-linked Polyethylene (XLPE)
    : Black Polyvinyl Chloride (PVC) (Inner Sheath)
                                      : Black flame retardant polyvinyl chloride

                                          (PVC/ST2) (Outer Sheath)
                                    : Galvanized Steel Wires (Armor)
                                    : Maximum conductor temperature 90 °C
                           : Circuit voltage not exceeding 1200 V
    : 3500 V (Testing Voltage)

    Read more
  • FD-0.6/1KV-AL-CV

    FD-0.6/1KV-AL-CV

    Conductor : Concentric stranded and hard drawn alminium
    : Single-core : Size 10 mm²  up to 500 mm²
    : Multi-core : Size 10 mm²  up to 400 mm²
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Single-core : Natural (Translucent)
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Rated voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
    Read more
  • FD-0.6/1KV-AL-CV-SWA

    FD-0.6/1 KV-CV-SWA

    Conductor : Concentric stranded and hard drawn aluminium
    : Size 10 mm²  up to 400 mm² (Multi Core)
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Compound color or color tape
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Armor : Galvanized steel wires
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    : Rated voltage (U0 /U) 0.6/1 KV
    : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, IEC 60332-1

    : IEC 60332-3-24 (Cat.C)

    Read more
  • Placeholder

    FDLH-0.6/1KV-CE

    FDLH-0.6/1KV-CE

    Conductor : Non-compacted and compacted round annealed copper
    Single-core Size 1.5 mm²  up to 1000 mm²
    Insulation : Cross-Linked polyetylene (XLPE)
    Core identification

    : Single-crosss : Natural (Translucent)
    : 2 Cores : Blue, Brown
    : 3 Cores : Brown, Black, Gray
    : 4 Cores : Blue, Brown, Black, Gray

    Shield : Black Low smoke and zero halogen flame retardant polylefin (ST8)
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Related Voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502, IEC 60228, IEC 60332-1,

      IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2

    Read more
  • FHC

    FHC              : Hard drawn copper wires, concentric stranded conductor
                        : 10 mm2 up to 500 mm2 
                        : Stranding direction the outermost layer Z

    Read more
  • Placeholder

    FRLH-IE

    FRLH-IE

    Conductor : Non-compacted and compacted round annealed copper
    Size 1.5 mm²  up to 630 mm²
    Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen
    Core identification : Single-crosss : Black or Orange
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 450/750 Volts
    Related Voltage : 45 Volts between Line-to-Earth
    : 75 Volts between Line-to-Line
    Testing voltage : 2,500 Volts
    Reference standard

    : BS EN 50525-3-41, BS EN 60228, BS EN 60332-1,

      BS EN 60332-3-24 (Cat.C), BS EN 50267-2-2, BS EN 61034-2

     

    Read more
  • Placeholder

    FS/LH-0.6/1KV-XLPE(C)

    FS/LH-0.6/1KV-XLPE (C)

    Conductor : Non-compacted and compacted round annealed copper
    Single-core Size 1.5 mm²  up to 630 mm²
    Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen
    Core identification : Signle-cores: Blank or Orange
    Fire barier tape : Mica tape
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 600/1000 Volts
    Related Voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, BS 6387 (Cat.CWZ),

      IEC 60332-1, IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2

    Read more
  • HWA OR THWA-C

    THWA OR THWA-C    : Solid and stranded hard drawn aluminium wires (THWA)
                                    : Compact stranded hard drawn aluminium wires (THWA-C)
                                    : 10 mm2 up to 500 mm2
                                    : Black Polyvinyl Chloride (PVC)
                                    : Maximum conductor temperature 70 °C
                                    : Circuit voltage not exceeding 750 V 
                                    : 2500 V (Testing Voltage)

    Read more