Showing 1–12 of 18 results

  • 115 KV-CE

    For installation exposed, or in raceway, wet and dry location, or direct burial in ground.

    Read more
  • 18/30(36) KV-CV

    18/30(36) KV-CV       : compact and round stranded annealed copper
                                    : 35 mm2 up to 1000 mm2 (Single Core)
                                    : 35 mm2 up to 400 mm2 (3 Cores)
                                    : Cross-linked Polyethylene (XLPE)
                                    : Black Polyvinyl Chloride (PVC/ST2)
                                    : Copper Tape (Shield)
                                    : Maximum conductor temperature 90 Degree C
                                    : Circuit voltage not exceeding 36000 V
    Insulation shield layer : Semi-conducting covering remove at splices or terminals
                                    : 63000 V (Testing Voltage)

    Read more
  • 6/10(12) KV-CV

    6/10(12) KV-CV          : Compact and round stranded annealed copper
                                     : 16 mm2 up to 1000 mm2 (Single Core)
                                     : 16 mm2 up to 400 mm2 (3 Cores)
                                     : Cross-linked Polyethylene (XLPE)
                                     : Black Polyvinyl Chloride (PVC/ST2)
                                     : Copper Tape (Sheath)
                                     : Maximum conductor temperature 90 Degree C
                                     : Circuit voltage not exceeding 12000 V
    Insulation shield layer  : Semi-conducting covering remove at splices or terminals
                                     : 21000 V (Testing Voltage)

    Read more
  • 60227 IEC 01 THW

    Non-Sheathed Cables for Fixed Wiring

    Building wiring for installation on insulator or in raceway, dry location.

    Read more
  • 60227 IEC 02 THW (F)

    Flexible Cables 

    60227 IEC 02 THW (F)      : Flexible annealed copper wire

                                           : 1.5 mm2 up to 240 mm2

                                           : Polyvinyl Chloride (PVC/C)

                                           : Any Color (Single Core)

                                           : Maximum conductor temperature 70 °C

                                           : Circuit Voltage not exceeding 450/750 V

                                           : 2500 V (Testing Voltage)

    Read more
  • 60227 IEC 10 NYY

    Sheathed Cables for Fixed Wiring

    60227 IEC 10 NYY             : Solid and stranded annealed copper

                                            : 1.5 mm2 up to 10 mm2 (Solid)

                                            : 1.5 mm2 up to 35 mm2 (Stranded)

                                            : Polyvinyl chloride (PVC/C)

                                            : 2 Cores to 5 Cores

                                            : Black Polyvinyl Chloride (Inner Sheath) (PVC)

                                            : Black Polyvinyl Chloride (Outer Sheath) (PVC/ST4)

                                            : Maximum conductor temperature 70 °C

                                            : Circuit Voltage not exceeding 300/500 V

                                            : 2000 V (Testing Voltage)

    Read more
  • 60227 IEC 53 VCT

    Flexible Cables

    For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 53 VCT-G

    Flexible Cables

     For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 56

    60227 IEC 56

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

    Conductor : Flexible annealed copper wires
    Size 0.5 mm ² and 0.75 mm²
    Insulation : Polyvinyl chloride (PVC/E)
    Core identification : 2 Cores : Blue and Brown
    : 3 Cores : Brown, black and greyor Blue, Brown and Green/Yellow
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
    300 Volts between Line-to-Earth
    300 Volts between Line-to-Line
    Testing voltage : 2,000 Volts
    Reference standard : TIS 11 Part 5-2553, Table 11
    Read more
  • 69 KV-CE

    For installation exposed, or in raceway, wet and dry location, or direct burial in ground.

    Read more
  • CVV or CVV-S

    For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.

    Read more
  • FD 0.6/1 KV-CV

    FD 0.6/1 KV-CV                  : Concentric Stranded and compacted round annealed copper

                                             : 1.5 mm2 up to 1000 mm2 (Single Core)

                                             : 1.5 mm2 up to 400 mm2 (Multi Cores)

                                             : Single core to 4 cores

                                             : Cross-linked Polyethylene (XLPE)

                                             : Black flame retardant polyvinyl chloride (PVC/ST2)

                                             : Maximum conductor temperature 90 °C

                                             : Circuit voltage not exceeding 1200 V

                                             : 3500 V (Testing Voltage)

    Read more