Showing 1–12 of 15 results

  • 24 KV-OC

    24 KV-OC                              : Compacted round stranded hard drawn aluminium wires

                                                : 35 mm2 up to 185 mm2

                                                : Cross-linked Polyethylene (XLPE)

                                                : Maximum conductor temperature 90 °C

                                                : Circuit voltage not exceeding 24 KV

                                                : 11 KV (Testing Voltage)

    Read more
  • 33KV-OC

    33 KV-OC

    Conductor : Compacted round stranded hard drawn aluminium wires
    : Single-core : Size 35 mm²  up to 185 mm²
    Insulation : Black Cross-linked polyethylene (XLPE)
    Core indentification : Color : Black
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 33,000 Volts
    Testing voltage : 17,000 Volts
    Reference standard : ICEA S-66-524, ICEA S-93-639
    Read more
  • 60227 IEC 01 THW

    Non-Sheathed Cables for Fixed Wiring

    Building wiring for installation on insulator or in raceway, dry location.

    Read more
  • 60227 IEC 02 THW (F)

    Flexible Cables 

    60227 IEC 02 THW (F)      : Flexible annealed copper wire

                                           : 1.5 mm2 up to 240 mm2

                                           : Polyvinyl Chloride (PVC/C)

                                           : Any Color (Single Core)

                                           : Maximum conductor temperature 70 °C

                                           : Circuit Voltage not exceeding 450/750 V

                                           : 2500 V (Testing Voltage)

    Read more
  • 60227 IEC 10 NYY

    Sheathed Cables for Fixed Wiring

    60227 IEC 10 NYY             : Solid and stranded annealed copper

                                            : 1.5 mm2 up to 10 mm2 (Solid)

                                            : 1.5 mm2 up to 35 mm2 (Stranded)

                                            : Polyvinyl chloride (PVC/C)

                                            : 2 Cores to 5 Cores

                                            : Black Polyvinyl Chloride (Inner Sheath) (PVC)

                                            : Black Polyvinyl Chloride (Outer Sheath) (PVC/ST4)

                                            : Maximum conductor temperature 70 °C

                                            : Circuit Voltage not exceeding 300/500 V

                                            : 2000 V (Testing Voltage)

    Read more
  • 60227 IEC 53 VCT

    Flexible Cables

    For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 53 VCT-G

    Flexible Cables

     For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 56

    60227 IEC 56

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

    Conductor : Flexible annealed copper wires
    Size 0.5 mm ² and 0.75 mm²
    Insulation : Polyvinyl chloride (PVC/E)
    Core identification : 2 Cores : Blue and Brown
    : 3 Cores : Brown, black and greyor Blue, Brown and Green/Yellow
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
    300 Volts between Line-to-Earth
    300 Volts between Line-to-Line
    Testing voltage : 2,000 Volts
    Reference standard : TIS 11 Part 5-2553, Table 11
    Read more
  • AAC

    AAC  : Concentric stranded hard drawn aluminium wires
    (All Aluminium Conductor)     : 16 mm2 up to 1000 mm2
                                              : outermost layer Z

    Read more
  • ACSR

    ACSR            : Hard drawn aluminium wire
                        : 16 mm2 up to 680 mm2 
                        : Galvanized steel (Zinc coated), solid and concentric stranded, 2.5 mm2 up to 85 mm2
                        : outermost layer Z

    Read more
  • FD-0.6/1KV-AL-CV

    FD-0.6/1KV-AL-CV

    Conductor : Concentric stranded and hard drawn alminium
    : Single-core : Size 10 mm²  up to 500 mm²
    : Multi-core : Size 10 mm²  up to 400 mm²
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Single-core : Natural (Translucent)
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Rated voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
    Read more
  • FD-0.6/1KV-AL-CV-SWA

    FD-0.6/1 KV-CV-SWA

    Conductor : Concentric stranded and hard drawn aluminium
    : Size 10 mm²  up to 400 mm² (Multi Core)
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Compound color or color tape
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Armor : Galvanized steel wires
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    : Rated voltage (U0 /U) 0.6/1 KV
    : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, IEC 60332-1

    : IEC 60332-3-24 (Cat.C)

    Read more