Showing all 15 results

  • 24 KV-OC

    24 KV-OC                              : Compacted round stranded hard drawn aluminium wires

                                                : 35 mm2 up to 185 mm2

                                                : Cross-linked Polyethylene (XLPE)

                                                : Maximum conductor temperature 90 °C

                                                : Circuit voltage not exceeding 24 KV

                                                : 11 KV (Testing Voltage)

    Read more
  • 33KV-OC

    33 KV-OC

    Conductor : Compacted round stranded hard drawn aluminium wires
    : Single-core : Size 35 mm²  up to 185 mm²
    Insulation : Black Cross-linked polyethylene (XLPE)
    Core indentification : Color : Black
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 33,000 Volts
    Testing voltage : 17,000 Volts
    Reference standard : ICEA S-66-524, ICEA S-93-639
    Read more
  • 60227 IEC 01 THW

    Non-Sheathed Cables for Fixed Wiring

    Building wiring for installation on insulator or in raceway, dry location.

    Read more
  • 60227 IEC 02 THW (F)

    Flexible Cables 

    60227 IEC 02 THW (F)      : Flexible annealed copper wire

                                           : 1.5 mm2 up to 240 mm2

                                           : Polyvinyl Chloride (PVC/C)

                                           : Any Color (Single Core)

                                           : Maximum conductor temperature 70 °C

                                           : Circuit Voltage not exceeding 450/750 V

                                           : 2500 V (Testing Voltage)

    Read more
  • 60227 IEC 10 NYY

    Sheathed Cables for Fixed Wiring

    60227 IEC 10 NYY             : Solid and stranded annealed copper

                                            : 1.5 mm2 up to 10 mm2 (Solid)

                                            : 1.5 mm2 up to 35 mm2 (Stranded)

                                            : Polyvinyl chloride (PVC/C)

                                            : 2 Cores to 5 Cores

                                            : Black Polyvinyl Chloride (Inner Sheath) (PVC)

                                            : Black Polyvinyl Chloride (Outer Sheath) (PVC/ST4)

                                            : Maximum conductor temperature 70 °C

                                            : Circuit Voltage not exceeding 300/500 V

                                            : 2000 V (Testing Voltage)

    Read more
  • 60227 IEC 53 VCT

    Flexible Cables

    For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 53 VCT-G

    Flexible Cables

     For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 56

    60227 IEC 56

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

    Conductor : Flexible annealed copper wires
    Size 0.5 mm ² and 0.75 mm²
    Insulation : Polyvinyl chloride (PVC/E)
    Core identification : 2 Cores : Blue and Brown
    : 3 Cores : Brown, black and greyor Blue, Brown and Green/Yellow
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
    300 Volts between Line-to-Earth
    300 Volts between Line-to-Line
    Testing voltage : 2,000 Volts
    Reference standard : TIS 11 Part 5-2553, Table 11
    Read more
  • AAC

    AAC  : Concentric stranded hard drawn aluminium wires
    (All Aluminium Conductor)     : 16 mm2 up to 1000 mm2
                                              : outermost layer Z

    Read more
  • ACSR

    ACSR            : Hard drawn aluminium wire
                        : 16 mm2 up to 680 mm2 
                        : Galvanized steel (Zinc coated), solid and concentric stranded, 2.5 mm2 up to 85 mm2
                        : outermost layer Z

    Read more
  • FD-0.6/1KV-AL-CV

    FD-0.6/1KV-AL-CV

    Conductor : Concentric stranded and hard drawn alminium
    : Single-core : Size 10 mm²  up to 500 mm²
    : Multi-core : Size 10 mm²  up to 400 mm²
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Single-core : Natural (Translucent)
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Rated voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
    Read more
  • FD-0.6/1KV-AL-CV-SWA

    FD-0.6/1 KV-CV-SWA

    Conductor : Concentric stranded and hard drawn aluminium
    : Size 10 mm²  up to 400 mm² (Multi Core)
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Compound color or color tape
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Armor : Galvanized steel wires
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    : Rated voltage (U0 /U) 0.6/1 KV
    : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, IEC 60332-1

    : IEC 60332-3-24 (Cat.C)

    Read more
  • HWA OR THWA-C

    THWA OR THWA-C    : Solid and stranded hard drawn aluminium wires (THWA)
                                    : Compact stranded hard drawn aluminium wires (THWA-C)
                                    : 10 mm2 up to 500 mm2
                                    : Black Polyvinyl Chloride (PVC)
                                    : Maximum conductor temperature 70 °C
                                    : Circuit voltage not exceeding 750 V 
                                    : 2500 V (Testing Voltage)

    Read more
  • VAF (or) VAF-G

    Sheathed Cables for General Purposes

    VAF or VAF-G                     : Solid and stranded annealed copper

                                             : 1 mm2 up to 16 mm2

                                             : Polyvinyl Chloride (PVC/C)

                                             : 2 Cores (VAF)/ 2Cores + G (VAF-G)

                                             : White Polyvinyl Chloride (PVC/ST4)

                                             : Maximum conductor temperature 70 °C

                                             : Circuit Voltage not exceeding 300/500 V

                                             : 2000 V (Testing Voltage)

    Read more
  • VTA

          SCOPE : This specification covers Lead Free PVC plastic electrical insulation tape to be used in electrical service at temperature 0  ~ 80°C. The tape shall be used for insulation of jointed splices of cables and wires. The tape must have good insulation properties, heat, weather, flame resistance, and lead free materials for environment, suitable for tropical country.
    Read more