Medical Printer P-95DW
High-Speed Printing
Prints 3.9 x 2.9″ images in just 1.9 seconds
Six Printing Sizes
Prints a range of sizes to meet all hospital print size needs
Dependable, High Resolution Images
High-density thermal head and thermal recording mode reproduce precise lighting and shade
High resolution 1280 x 500 pixels and 256 grades for normal size printing (horizontal picture element density of 325 dpi)
Easy to Operate
Convenient user interface features all principal functions accessible from the front panel, along with LED indicators for most settings
Compact Thermal Printer
Ultra-thin printing mechanism reduces installation space
Worldwide Compatibility
100-240V power supply
Compatible with UL 2601-1 & CE(LVD,MDD) -
Medical Printer CP-30W
Dependable, High Resolution Images
423 dpi high resolution
New adaptive thermal head management control engine
High Speed Output
Prints S-size output in 16 seconds and L-size output in 25 seconds
Automatic Loading for Trouble-Free Ribbon Cartridge Replacement
Single-action operation for easy ribbon cartridge replacement
Easy View Front Design
Printer operation panel functions are displayed on the front LED display unit
Paper Cassette Engineered for Easy Mounting
Fast and easy media replacement
Compact Design
Compact unit size for easy integration into any environment
Wide-Mouth Paper Catcher
Extra roomy – print retrieval is easier than ever
Effective Heat and Dust Case Design
Provides efficient cooling of the thermal head and power supply unit -
VTA
     SCOPE : This specification covers Lead Free PVC plastic electrical insulation tape to be used in electrical service at temperature 0  ~ 80°C. The tape shall be used for insulation of jointed splices of cables and wires. The tape must have good insulation properties, heat, weather, flame resistance, and lead free materials for environment, suitable for tropical country. -
-
-
33KV-OC
33 KV-OC
Conductor : Compacted round stranded hard drawn aluminium wires
: Single-core : Size 35 mm² up to 185 mm²Insulation : Black Cross-linked polyethylene (XLPE) Core indentification : Color : Black Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 33,000 VoltsTesting voltage : 17,000 Volts Reference standard : ICEA S-66-524, ICEA S-93-639 -
24 KV-OC
24 KV-OC Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â :Â Compacted round stranded hard drawn aluminium wires
                                           : 35 mm2 up to 185 mm2
                                           : Cross-linked Polyethylene (XLPE)
                                           : Maximum conductor temperature 90 °C
                                           : Circuit voltage not exceeding 24 KV
                                           : 11 KV (Testing Voltage)
-
FD-0.6/1KV-AL-CV-SWA
FD-0.6/1 KV-CV-SWA
Conductor : Concentric stranded and hard drawn aluminium
: Size 10 mm² up to 400 mm² (Multi Core)Insulation : Cross-linked Polyethylene (XLPE) Core identification : Compound color or color tape
: 2 Core : Blue and Brown
: 3 Core : Brown, Black and Grey
: 4 Core : Blue, Brown, Black and Grey
: Other colors are available on customer requestArmor : Galvanized steel wires Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2) Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 1,200 Volts
: Rated voltage (U0Â /U) 0.6/1 KV
: 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
: IEC 60332-3-24 (Cat.C)
-
FD-0.6/1KV-AL-CV
FD-0.6/1KV-AL-CV
Conductor : Concentric stranded and hard drawn alminium
: Single-core : Size 10 mm² up to 500 mm²
: Multi-core : Size 10 mm² up to 400 mm²Insulation : Cross-linked Polyethylene (XLPE) Core identification : Single-core : Natural (Translucent)
: 2 Core : Blue and Brown
: 3 Core : Brown, Black and Grey
: 4 Core : Blue, Brown, Black and Grey
: Other colors are available on customer requestSheath : Black Flame retardant polyvinyl chloride (PVC/ST2) Classification : Maximum conductor temperature 90°C
: Circuit voltage not exceeding 1,200 VoltsRated voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1 -
HWA OR THWA-C
THWA OR THWA-CÂ Â Â : Solid and stranded hard drawn aluminium wires (THWA)
                        : Compact stranded hard drawn aluminium wires (THWA-C)
                         : 10 mm2 up to 500 mm2
                          : Black Polyvinyl Chloride (PVC)
                         : Maximum conductor temperature 70 °C
                         : Circuit voltage not exceeding 750 VÂ
                         : 2500 V (Testing Voltage) -
-
FS/LH-0.6/1KV-XLPE(C)
FS/LH-0.6/1KV-XLPE (C)
Conductor : Non-compacted and compacted round annealed copper
Single-core Size 1.5 mm² up to 630 mm²Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen Core identification : Signle-cores: Blank or Orange Fire barier tape : Mica tape Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 600/1000 VoltsRelated Voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502-1, IEC 60228, BS 6387 (Cat.CWZ),
 IEC 60332-1, IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2
-
FDLH-0.6/1KV-CE
FDLH-0.6/1KV-CE
Conductor : Non-compacted and compacted round annealed copper
Single-core Size 1.5 mm² up to 1000 mm²Insulation : Cross-Linked polyetylene (XLPE) Core identification : Single-crosss : Natural (Translucent)
: 2 Cores : Blue, Brown
: 3 Cores : Brown, Black, Gray
: 4 Cores : Blue, Brown, Black, GrayShield : Black Low smoke and zero halogen flame retardant polylefin (ST8) Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 1,200 VoltsRelated Voltage : 600 Volts between Line-to-Earth
: 1,000 Volts between Line-to-LineTesting voltage : 3,500 Volts Reference standard : IEC 60502, IEC 60228, IEC 60332-1,
 IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2
-
FRLH-IE
FRLH-IE
Conductor : Non-compacted and compacted round annealed copper
Size 1.5 mm² up to 630 mm²Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen Core identification : Single-crosss : Black or Orange Classification : Maximum concuctortemperature 90°C
: Circuit voltage not exceeding 450/750 VoltsRelated Voltage : 45 Volts between Line-to-Earth
: 75 Volts between Line-to-LineTesting voltage : 2,500 Volts Reference standard : BS EN 50525-3-41, BS EN 60228, BS EN 60332-1,
 BS EN 60332-3-24 (Cat.C), BS EN 50267-2-2, BS EN 61034-2
-
CVV or CVV-S
For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.
-
-
-
18/30(36) KV-CV
18/30(36) KV-CVÂ Â Â Â Â : compact and round stranded annealed copper
                     : 35 mm2 up to 1000 mm2 (Single Core)
                     : 35 mm2 up to 400 mm2 (3 Cores)
                      : Cross-linked Polyethylene (XLPE)
                     : Black Polyvinyl Chloride (PVC/ST2)
                      : Copper Tape (Shield)
                   : Maximum conductor temperature 90 Degree C
                   : Circuit voltage not exceeding 36000 V
Insulation shield layer : Semi-conducting covering remove at splices or terminals
                     : 63000 V (Testing Voltage) -
6/10(12) KV-CV
6/10(12) KV-CVÂ Â Â Â Â Â Â : Compact and round stranded annealed copper
                         : 16 mm2 up to 1000 mm2 (Single Core)
                         : 16 mm2 up to 400 mm2 (3 Cores)
                          : Cross-linked Polyethylene (XLPE)
                          : Black Polyvinyl Chloride (PVC/ST2)
                          : Copper Tape (Sheath)
                          : Maximum conductor temperature 90 Degree C
                          : Circuit voltage not exceeding 12000 V
Insulation shield layer : Semi-conducting covering remove at splices or terminals
                 : 21000 V (Testing Voltage) -
FD 0.6/1 KV-CV-SWA
FD 0.6/1 KV-CV-SWAÂ Â Â Â : Concentric stranded and compact stranded annealed copper
: 1.5mm2 up to 400 mm2
: 2 cores to 4 cores
: Cross-linked Polyethylene (XLPE)
: Black Polyvinyl Chloride (PVC) (Inner Sheath)
                   : Black flame retardant polyvinyl chloride                                     (PVC/ST2) (Outer Sheath)
                 : Galvanized Steel Wires (Armor)
                   : Maximum conductor temperature 90 °C
              : Circuit voltage not exceeding 1200 V
: 3500 V (Testing Voltage)