Categories

Product Categories

Showing 101–120 of 239 results

  • FD 0.6/1 KV-CV-SWA

    FD 0.6/1 KV-CV-SWA     : Concentric stranded and compact stranded annealed copper
    : 1.5mm2 up to 400 mm2
    : 2 cores to 4 cores
    : Cross-linked Polyethylene (XLPE)
    : Black Polyvinyl Chloride (PVC) (Inner Sheath)
                                      : Black flame retardant polyvinyl chloride

                                          (PVC/ST2) (Outer Sheath)
                                    : Galvanized Steel Wires (Armor)
                                    : Maximum conductor temperature 90 °C
                           : Circuit voltage not exceeding 1200 V
    : 3500 V (Testing Voltage)

    Read more
  • FD 0.6/1 KV-CV

    FD 0.6/1 KV-CV                  : Concentric Stranded and compacted round annealed copper

                                             : 1.5 mm2 up to 1000 mm2 (Single Core)

                                             : 1.5 mm2 up to 400 mm2 (Multi Cores)

                                             : Single core to 4 cores

                                             : Cross-linked Polyethylene (XLPE)

                                             : Black flame retardant polyvinyl chloride (PVC/ST2)

                                             : Maximum conductor temperature 90 °C

                                             : Circuit voltage not exceeding 1200 V

                                             : 3500 V (Testing Voltage)

    Read more
  • 60227 IEC 53 VCT-G

    Flexible Cables

     For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 53 VCT

    Flexible Cables

    For household appliances, electrical equipment and electrical illumination.

    Read more
  • 60227 IEC 10 NYY

    Sheathed Cables for Fixed Wiring

    60227 IEC 10 NYY             : Solid and stranded annealed copper

                                            : 1.5 mm2 up to 10 mm2 (Solid)

                                            : 1.5 mm2 up to 35 mm2 (Stranded)

                                            : Polyvinyl chloride (PVC/C)

                                            : 2 Cores to 5 Cores

                                            : Black Polyvinyl Chloride (Inner Sheath) (PVC)

                                            : Black Polyvinyl Chloride (Outer Sheath) (PVC/ST4)

                                            : Maximum conductor temperature 70 °C

                                            : Circuit Voltage not exceeding 300/500 V

                                            : 2000 V (Testing Voltage)

    Read more
  • VAF (or) VAF-G

    Sheathed Cables for General Purposes

    VAF or VAF-G                     : Solid and stranded annealed copper

                                             : 1 mm2 up to 16 mm2

                                             : Polyvinyl Chloride (PVC/C)

                                             : 2 Cores (VAF)/ 2Cores + G (VAF-G)

                                             : White Polyvinyl Chloride (PVC/ST4)

                                             : Maximum conductor temperature 70 °C

                                             : Circuit Voltage not exceeding 300/500 V

                                             : 2000 V (Testing Voltage)

    Read more
  • 60227 IEC 56

    60227 IEC 56

    300/300 V 90°C FLEXIBLE CONDUCTOR PVC INSULATED AND SHEATHED, ROUND TYPE

    Conductor : Flexible annealed copper wires
    Size 0.5 mm ² and 0.75 mm²
    Insulation : Polyvinyl chloride (PVC/E)
    Core identification : 2 Cores : Blue and Brown
    : 3 Cores : Brown, black and greyor Blue, Brown and Green/Yellow
    Outer sheath : Black polyvinyl chloride (PVC/ST10)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 300/300 Volts
    300 Volts between Line-to-Earth
    300 Volts between Line-to-Line
    Testing voltage : 2,000 Volts
    Reference standard : TIS 11 Part 5-2553, Table 11
    Read more
  • 60227 IEC 02 THW (F)

    Flexible Cables 

    60227 IEC 02 THW (F)      : Flexible annealed copper wire

                                           : 1.5 mm2 up to 240 mm2

                                           : Polyvinyl Chloride (PVC/C)

                                           : Any Color (Single Core)

                                           : Maximum conductor temperature 70 °C

                                           : Circuit Voltage not exceeding 450/750 V

                                           : 2500 V (Testing Voltage)

    Read more
  • 60227 IEC 01 THW

    Non-Sheathed Cables for Fixed Wiring

    Building wiring for installation on insulator or in raceway, dry location.

    Read more
  • Greystone Humidity Sensor

    Greystone Humidity Sensor

    High Accuracy Room Humidity transmitter
    (Greystone)/(Made in Canada)

    Read more
  • Greystone Room temperature Sensor

    Greystone Room temperature Sensor

    High Accuracy Room temperature Sensor
    (Greystone)/Made in Canada)

    Read more
  • Greystone CO2 Sensor

    Greystone CO2 Sensor

    Room CARBONDIOXIDE
    DETECTOR (GREY STONE)
    (Made in Canada)

    Part Number

    CDD4 Series

    Product Line Up

    CDD4A10-( 0-2000 ppm)

    CDD4B10-( 0-20,000 ppm)

    Read more
  • GOT2000 Series

    iQ Platform
    Graphic Operation Terminal
    GOT2000 Series

    Read more
  • SCADA Software

    It may be difficult to effectively represent equipment monitoring
    using only two-dimensional graphics. On the other hand,
    three-dimensional graphics can enhance the visibility with its
    stereoscopic displays.
    Three-dimensional graphics allow you to have monitor views
    from various angles. This enables you to: know the condition of
    equipment quickly and accurately, have instinctive monitoring
    views and make intuitive control
    MC Works64 enables you to construct redundant server systems
    and server-and-client systems.
    It is possible to utilize two servers, a control server and a standby
    server, to enhance the reliability of the system and to reduce the
    communication load on the network.
    It is possible to embody a configuration suitable for the system
    size, from a stand-alone system to a large-scale system.
    Various equipment lists are available to automatically generate
    graphics, programs, and OPC tag settings. The design support tool
    prevents incorrect tag settings, thus enhancing the design quality.
    Standard templates facilitate system configuration.
    By monitoring energy consumption, energy use can be reduced
    over time.
    Energy consumption can be visualized through the integration
    of Mitsubishi Electric’s energy measurement equipment and AX
    Energy; an energy analysis and visualization tool.
    The lineup of Mitsubishi Electric’s energy-saving equipment that
    includes the inverter with enhanced motor control efficiency will
    reduce energy consumption at your plant.
    Mitsubishi Electric’s MES interface module can be used to collect
    information on production control. AX Facility can then display and
    analyze the diagnosis and equipment failure information.
    These products automatically collect the information on the
    condition of equipment from a large amount of data, using it for
    the improvement of: the availability factor, preventive maintenance,
    fault prediction etc.
    Read more
  • FR A700 series

    • Highest level of driving performance
    “Advanced driving performance makes it possible to support a wide
    range of applications from variable-speed applications such as
    conveyance and chemical machines to line control applications such
    as winding machines and printing machines”

    • Long life parts and life check function
    “Adoption of long life parts ensures more reliable operation.
    The reliable life diagnosis function notifies the maintenance time.”

    • Network connection as you desired
    “It is compatible with CC-Link communication, SSCNET and other
    major overseas networks. The inverter can be controlled or monitored
    via network from the controller.”

    •Environmental conciousness
    “Noise measures are available without an option.
    Harmonic currents technique is available with a new type reactor.”

    Read more
  • FR D700 series

    •Safety stop function
    “The FR-D700 series is compliant to the EU
    Machinery Directive without the addition of
    previously required external devices.
    Operation of an external Emergency
    Stop device results in a highly reliable
    immediate shutoff of the D700’s output to
    the motor.
    This safety stop function conforms to the
    following standar”

    •Spring clamp terminal (control circuit terminal)
    With spring clamp terminals, the wiring became easier and more secure.

    •Long-life design
    “The design life of the cooling fan has been extended to 10
    years*1. The life of the fan can be further extended utilizing the
    it’s ON/OFF control.
    The design life of the capacitors has been extended to 10
    years by the adoption of a capacitor endures 5000 hours at
    105°C surrounding air temperature”

    •Leading life check function
    “Degrees of deterioration of main circuit capacitor, control
    circuit capacitor, and inrush current limit circuit can be
    monitored.
    Trouble can be avoided with the self-diagnostic alarm that is
    output when the life span is near.”

    •Password function
    “Registering a 4-digit password can limit parameter read/write.

    It is effective for parameter setting
    protection.”

    Read more
  • FR E700 series

    (1) A variety of plug-in options are mountable
    “Plug-in options supporting digital input, analog output extension, and a variety of communications provide extended functions which is
    almost equivalent to the FR-A700 series. (One type of plug-in option can be mounted.)”

    (2) Safety stop function (FR-E700-SC)
    “•Spring clamp terminals are adopted as control circuit terminals.
    Spring clamp terminals are highly reliable and can be easily wired.
    •The FR-E700-SC series is compliant to the EU Machinery Directive
    without the addition of previously required external devices.
    Operation of an external Emergency Stop device results in a
    highly reliable immediate shutoff of the D700’s output to the motor.
    This safety stop function conforms to the following standa”

    (3) Control terminals are selectable according to applications
    “Terminal cards other than standard terminal such as two port RS-485 terminal are
    available as options.
    A terminal card is removable and can be easily replaced from a standard terminal
    card.”

    (4) Various kinds of networks are supported
    “EIA-485 (RS-485), ModbusRTU (equipped as standard), CC-Link,
    PROFIBUS-DP, DeviceNet®, LONWORKS® (option)”

    Read more
  • FR F700P series

    “•The “”F700P inverter for fans and pumps”” can drive both general-purpose motors
    (3-phase induction motors) and IPMmotors. The F700P could be thesolution to your energy saving need”            
                
    (1) Energy saving with speed con            
    ” The consumed power of a variable-torque load, such as fans, pumps, and blowers, is proportional to the cube of its rotation speed.
    This means that controlling the rotation speed to adjust the air volume
    can lead to energy savings”            
                
    (2) Energy saving with Optimum excitation control (General-purpose motors)            
    ” Optimum excitation control continuously adjusts the excitation
    current to an optimum level to provide the highest motor efficiency, and that leads to substantial energy savings. ”            
                
    (3) Energy saving with IPM motors            
    •High efficiency achieved with IPM motors            
    The IPM motors that have permanent magnets embedded in their rotors            
    are even more efficient than the high-performance energy-saving motors.            
                
    (4)Various Functions for Fans and Pumps            
         (1) Variable-torque acceleration/deceleration pattern            
         Variable torque loads suchas fans and blowers can be accelerated/decelerated in a short period of time.            
                
         (2) Full-scale PID function            
         To save energy in low-speed operation: PID output shutoff (sleep) function            
         To shorten the start-up time of PID control: PID automatic switchover function            
         For air conditioning applications: Forward/reverse rotation switching by external signals            
         To use various types of detectors: PID set point and measured value outputs in            
         voltage (0 to 5V / 0 to 10V) and current (4 to 20mA)            
                
          (3) Complete I/O terminals come standard            
          Contact input (12 terminals), analog input (3 terminals), open            
          collector output (5 terminals), relay output (2 terminals), analog            
          output, and pulse train output come standard. Various functions            
          can be assigned to these terminals.            
          Voltage and current are selectable for analog input.            
          ON/OFF status of the signals inputted to or outputted from th  I/O terminals can be displayed on the operation panel.            
                     
         (4) Automatic acceleration/deceleration time switchover            
    ”      A frequency where the acceleration/deceleration time is changed can be pre-set; an
          external switch is not required to switch the time setting. This function is especially
          useful for an operation thatrequires high torque in alow speed operation”            
         (5) Password function            
         Parameter writing/reading can be restrictedwith a 4-digit password.            
         This function is useful to prevent parameter values from being rewritten by misoperation            
                
         (6) Keep running during instantaneous power failure            
         Automatic restart after instantaneous power failure function / flyinstart function.            
         After an instantaneous power failure, the operation is re-startable from the coasting motor speed.            
         Even if the rotation direction has been forcibly reversed, the operation can be            
         smoothly restarted in the original direction.            
         Power failure time deceleration-to-stop function.            
         During operations of fans and blowers, the operation is continued at an            
         instantaneous power failure without the motor coasting            
                
        (7) Energy saving effect checked at a glance            
        The energy saving effect can be checked on the energy saving monitor.            
        The measured output power amount can be output in pulses.         

    Read more
  • FR – F800 SERIES

    FR – F800 SERIES
    Enhanced Next-Generation Energy-Saving Inverter

    Specialty        :    Advanced speed controls & standard controls
    Availability      :    3 – phase 200V class, [ 0.75 KW  to110 KW ]
    3 – phase 400V class, [ 0.75 KW  to 560 KW ]
    Usages          :    Fan & Pump etc.
    Warranty        :    1 year
    Specification   :    Refer here. For more details, please refer to the catalogues.

    FEATURES
    Energy saving

    •    Advanced optimum excitation control, which has been newly developed, provides a large starting torque while maintaining the motor efficiency under the conventional Optimum excitation control.
    •    The tuning function enables operation of other manufacturers’ induction motors and PM motors, which increases the use in the energy saving applications.
    •    With the 24 VDC external power supply, the input MC signal can be turned OFF after the motor is stopped, and turned ON before activating the motor. The inverter enables self-power management to reduce standby power.
    Functions ideal for fans and pumps
    •    The rating can be selected between the two types (LD (light duty) or SLD (superlight duty)) depending on the load of the fan/pump to be used (multiple rating).
    •    The inverter can perform PID control of the motor operation and control the external equipment at the same time (PID multiple loops). The system cost can be reduced.
    •    By controlling the pumps connected in parallel (up to four pumps) by the PID control, water volume, etc. can be adjusted by one inverter (multi-pump function).
    •    Foreign matter on the impellers or fans of pumps can be removed by repeating forward/reverse rotation and stopping of the motor (cleaning function).
    Security & safety
    •    Controls with safety functions can be easily performed (safety stop function).
    •    With the 24 VDC external power supply, the parameter setting and communication operation can be done without turning ON the main circuit power.
    •    The inverter is equipped with a temperature sensor, which outputs a signal when the internal temperature is high.
    •    The operating status immediately before the protective function is activated can be stored (trace function). A USB memory device and the inverter setup software (FR Configurator2) facilitate the trouble analysis at a separate location.
    Compatibility with the environment
    •    A built-in noise filter (EMC filter) minimizes the EMI emitted from inverters.
    •    By installing a DC reactor (FR-HEL), which is available as an option, they can conform to the Architectural Standard Specifications (2013 revision) supervised by the Ministry of Land, Infrastructure, Transport and Tourism of Japan.
    Easy setup & easy to use
    •    A USB host connecter (A type) is equipped. Parameters can be copied to commercial USB memory devices.
    •    Highly reliable and easily wired spring clamp terminals have been adopted for control circuit terminals.

    Read more
  • FR – A800 SERIES

    FR – A800 SERIES
    Unparalleled Performance. Uncompromising Quality.

    Specialty        :    Advanced torque controls & standard controls
    Availability     :    3 – phase 200V class, [ 0.4 KW  to  90 KW ]
    3 – phase 400V class, [ 0.4 KW  to  500 KW ]
    Usages           :    Transfer, Lift, Food Packaging, Machine tool, Press, Printing & Winding/Unwinding etc.
    Warranty        :    1 year
    Specification  :    Refer here . For more details, please refer to the catalogues.

    FEATURES

    Leading drive performance

    • The enhanced Real sensorless vector control and vector control achieves improved speed response and high-speed operation.
    • The PM motor auto tuning function enables operation of other manufacturers’ permanent magnet (PM) motors.

    Security & safety

    • Controls with safety functions can be easily performed. (Safety stop function)
    • 24 VDC control power input is equipped as standard. The parameter setting and communication operation can be done without turning ON the main power.
    • The operating status immediately before the protective function is activated can be stored with the trace function, facilitating the trouble analysis at a separate location by using a USB memory device and the inverter setup software (FR Configurator2).

    Easy setup & easy to use

    • A USB host connecter (A type) is equipped. Parameters can be copied to commercial USB memory devices.
    • Highly reliable and easily wired spring clamp terminals have been adopted for control circuit terminals.
    • Parameter setting mode can be changed to the group parameter mode, which provides intuitive and simple parameter settings. (The conventional parameter setting mode is selected by default.)

    Eco-friendly factories

    • With Optimum excitation control, the excitation current is constantly adjusted to drive the motor in the most efficient method which leads to energy saving.
    • The 315K or higher models are inverter-converter separated types, which are suitable for power regeneration. Select the FR-CC2 converter unit according to the connected motor capacity.

    System support

    • Rated current and four different overload capacity ratings (SLD rating, LD rating, ND rating, and HD rating) can be selected with parameters. (Multiple rating)
    • Parameters and setting frequency can be changed at the program, and the inverter control based on the machine specifications is possible by the PLC function.
    • A lineup of products compatible with the IP55 (400 V class) equipped with the DC reactor is available. Inverters can be installed nearby the machine.

    Environmental adaptability

    • A built-in noise filter (EMC filter), the newly developed drive technology, and the power supply technology minimize the EMI emitted from inverters.
    Read more