Categories
Product Categories
-
-
-
-
-
RISH LM 1360 / 1350 -Load Manager
Accuracy class 0.2S and 0.5 as per IEC 62053-22
THD and Individual Harmonics Measurement upto 31st
USB Interface with RTC(Real Time Clock)
Event logging for daily,monthly and yearly analysis
Load Profile Analysis with 8 Mb In built memory
Big LCD display with Back-lit
On-site Fully programmable CT/PT rations
Compliance to International Safety standards IEC 61010
Limit (Alarm) or Pulse or RTC relay or Timer Relay Output (optional)
Direct remote access(Optional)
Plug & Play CT with RJ12 option – Accuracy Class 1
-
Touch Screen – Rish Master 3440i / Rish Master 3440iDL : Class 0.2s
Touch Screen – Rish Master 3440i / Rish Master 3440iDL : Class 0.2s
-
-
RISH ML 1400 / ML 1410 (MultiLoad Monitor)
- Multiple Circuit Monitoring ( 4x 3ph or 12x 1ph) – System Transparency @ a glance
- Unmatched Energy Saving
- Residual Current Monitoring and tripping
- Prepaid Tariff based tripping
- Health Monitoring of Three Phase Load
- Data logging (Event based, Time based, Load profile based)
- Plug and Play Current transformer (RJ12 connections)
- Multiple class option (Class 1 or Class 0.5s as per IEC 62053)
- On-site fully programmable
- Direct remote access via communication (Modbus – RTU, Modbus TCP/IP)
- Relay Output (optional 2 or 4)
- THD and Individual Harmonics Measurement ( upto 31st)
- RTC (Real Time Clock)
- Easy & Cost Effective Installations
- Big LCD display with Backlit (4 parameters along with 9 digit energy counter)
- Percentage load indication
- Flexible DIN Mounted QuickFix modules (RJ00, RJ01, RJ05, RC30)
-
Single channel DC Energy Meter – Rish
EMDC 6000
- Onsite Programmable
- Accuracy Class 0.5
- Data Logging with Real Time Clock
- Shunt Reverse Locking
-
-
-
De-tuned Harmonic Filter Reactors
- High harmonic loading capability
- Temperature Protection ( NC contact ) and natural cooling
- Low Noise and convenient mounting
- Long expected life time
- Available Voltage 400V and 440V with an output from 10KVar to 100KVar
-
Capacitor Contactors
- Improved power quality ( e.g. avoidance of voltage sags )
- Longer useful life of main contacts of capacitor contactor
- Enhanced mean life expectancy of PFC systems
- Tamper-proof and protected resistors
- Voltage range from 400V to 690V with an output range from 12.5KVar to 100KVar
-
PhiCap Capacitors
- Compact design in cylindrical aluminum can with stud
- Advanced Self-healing technology, Overpressure disconnector ( Safety of Explosion ) and Naturally air-cooled
- Voltage Range from 230V to 525V with an output range from 5KVar to 30KVar
- Long life expectancy of up to 135000 Hours
-
PF Controllers BR6000 Series
- Self-optimizing control capability
- Recall function of recorded values of Maximum Voltage, Power, Harmonics, Temperature, Active Power, No. of contactor switching operations
- Large measuring voltage range
- Powerful alarm output for insufficient compensation, over compensation, Current, Temperature, Internal Error Storage and etc…
- Display of numerous system parameters as System Voltage, Active and Reactive Power, Frequency, Real-time and Target Cosø, Harmonics (3rd …..19th), Energy and etc….
-
Power Quality Solutions (PQS) with EPCOS products for successful power factor correction
Advantages of Power Factor Correction:
- Increase in efficiency of system and devices
- Stable Voltage
- An Increase in available power
- Saving in the Electric bill
- Better usage of power system, lines and generators etc…
Saving in energy as well as rating and the cost of the electrical devices
-
Q-Auto / V
• Enhanced Reliability due to built in Microprocessor• Maintaining high power factor to save Energy• Cos phi can display, ITHD and Load• Automatically determine the value of C / k• Ratio flexible step can be programmed according to the needs• Alarm for voltage, current, harmonicsSetting the response time 5-300 second
-
Type RG-2 (oil type)
•The casing is made of steel•More heat resistant because in containing oil / oil serves as a coolant•Terminal capacitor made of porcelain•Equipped internal fuse (safety of explosion)•Voltage available 230V, 415V, 440V, 525V•Output 10 KVAR to 100 KVARLong service life (range 10-15 years) *
-
RF-T type (dry type)
Standard IEC 60831-1: 1996 60831-2: 1995 and JIS C.490.• The casing is made of aluminum.• 415V voltage, output ranging from 5KVAR to 30KVAR.For the needs of larger KVAR can auto-merge 2 or more capacitors (connected in parallel).
-
Low Voltage Series Reactor type LRB-3
Solve your harmonic problems with SHIZUKI Low Voltage Series Reactor type LRB-3 (harmonic filters)
Dry Type Indoor Use
- Standard IEC 60289 – 1998 and JIS C.4901 – 2000
- By reactance L – 6% more optimal in harmonic absorption than reactor L = 7 %
- Equipped sensor Thermal protection
- Coil of copper
- Can be paired with a capacitor type RG & RFT
- Available 230V and 415V voltage