  • Medical Printer P-93W

    High-Speed Printing
    Prints 3.9 x 3.0″ images (1280 x 500) in approximately 3.3 seconds
    Six Printing Sizes
    Prints a range of sizes to meet all hospital print size needs
    Dependable, High Resolution Images
    High-density thermal head and thermal recording mode reproduce precise lighting and shade
    High resolution 1280 x 500 pixels and 256 grades for normal size printing (horizontal picture element density of 325 dpi).
    Easy to Operate
    Convenient user interface features all principal functions accessible from the front panel, along with LED indicators for most settings
    Compact Thermal Printer
    Ultra-thin printing mechanism reduces installation space
    Worldwide Compatibility
    100-240V power supply
    Compatible with UL 2601-1 & CE(LVD,MDD)

    Read more
  • Medical Printer P-95DW

    High-Speed Printing
    Prints 3.9 x 2.9″ images in just 1.9 seconds
    Six Printing Sizes
    Prints a range of sizes to meet all hospital print size needs
    Dependable, High Resolution Images
    High-density thermal head and thermal recording mode reproduce precise lighting and shade
    High resolution 1280 x 500 pixels and 256 grades for normal size printing (horizontal picture element density of 325 dpi)
    Easy to Operate
    Convenient user interface features all principal functions accessible from the front panel, along with LED indicators for most settings
    Compact Thermal Printer
    Ultra-thin printing mechanism reduces installation space
    Worldwide Compatibility
    100-240V power supply
    Compatible with UL 2601-1 & CE(LVD,MDD)

    Read more
  • Medical Printer CP-30W

    Dependable, High Resolution Images
    423 dpi high resolution
    New adaptive thermal head management control engine
    High Speed Output
    Prints S-size output in 16 seconds and L-size output in 25 seconds
    Automatic Loading for Trouble-Free Ribbon Cartridge Replacement
    Single-action operation for easy ribbon cartridge replacement
    Easy View Front Design
    Printer operation panel functions are displayed on the front LED display unit
    Paper Cassette Engineered for Easy Mounting
    Fast and easy media replacement
    Compact Design
    Compact unit size for easy integration into any environment
    Wide-Mouth Paper Catcher
    Extra roomy – print retrieval is easier than ever
    Effective Heat and Dust Case Design
    Provides efficient cooling of the thermal head and power supply unit

    Read more
  • VTA

          SCOPE : This specification covers Lead Free PVC plastic electrical insulation tape to be used in electrical service at temperature 0  ~ 80°C. The tape shall be used for insulation of jointed splices of cables and wires. The tape must have good insulation properties, heat, weather, flame resistance, and lead free materials for environment, suitable for tropical country.
    Read more
  • ACSR

    ACSR            : Hard drawn aluminium wire
                        : 16 mm2 up to 680 mm2 
                        : Galvanized steel (Zinc coated), solid and concentric stranded, 2.5 mm2 up to 85 mm2
                        : outermost layer Z

    Read more
  • AAC

    AAC  : Concentric stranded hard drawn aluminium wires
    (All Aluminium Conductor)     : 16 mm2 up to 1000 mm2
                                              : outermost layer Z

    Read more
  • 33KV-OC

    33 KV-OC

    Conductor : Compacted round stranded hard drawn aluminium wires
    : Single-core : Size 35 mm²  up to 185 mm²
    Insulation : Black Cross-linked polyethylene (XLPE)
    Core indentification : Color : Black
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 33,000 Volts
    Testing voltage : 17,000 Volts
    Reference standard : ICEA S-66-524, ICEA S-93-639
    Read more
  • 24 KV-OC

    24 KV-OC                              : Compacted round stranded hard drawn aluminium wires

                                                : 35 mm2 up to 185 mm2

                                                : Cross-linked Polyethylene (XLPE)

                                                : Maximum conductor temperature 90 °C

                                                : Circuit voltage not exceeding 24 KV

                                                : 11 KV (Testing Voltage)

    Read more
  • FD-0.6/1KV-AL-CV-SWA

    FD-0.6/1 KV-CV-SWA

    Conductor : Concentric stranded and hard drawn aluminium
    : Size 10 mm²  up to 400 mm² (Multi Core)
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Compound color or color tape
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Armor : Galvanized steel wires
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    : Rated voltage (U/U) 0.6/1 KV
    : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, IEC 60332-1

    : IEC 60332-3-24 (Cat.C)

    Read more
  • FD-0.6/1KV-AL-CV

    FD-0.6/1KV-AL-CV

    Conductor : Concentric stranded and hard drawn alminium
    : Single-core : Size 10 mm²  up to 500 mm²
    : Multi-core : Size 10 mm²  up to 400 mm²
    Insulation : Cross-linked Polyethylene (XLPE)
    Core identification : Single-core : Natural (Translucent)
    : 2 Core : Blue and Brown
    : 3 Core : Brown, Black and Grey
    : 4 Core : Blue, Brown, Black and Grey
    : Other colors are available on customer request
    Sheath : Black Flame retardant polyvinyl chloride (PVC/ST2)
    Classification : Maximum conductor temperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Rated voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard : IEC 60502-1, IEC 60228, IEC 60332-1
    Read more
  • HWA OR THWA-C

    THWA OR THWA-C    : Solid and stranded hard drawn aluminium wires (THWA)
                                    : Compact stranded hard drawn aluminium wires (THWA-C)
                                    : 10 mm2 up to 500 mm2
                                    : Black Polyvinyl Chloride (PVC)
                                    : Maximum conductor temperature 70 °C
                                    : Circuit voltage not exceeding 750 V 
                                    : 2500 V (Testing Voltage)

    Read more
  • FHC

    FHC              : Hard drawn copper wires, concentric stranded conductor
                        : 10 mm2 up to 500 mm2 
                        : Stranding direction the outermost layer Z

    Read more
  • Placeholder

    FS/LH-0.6/1KV-XLPE(C)

    FS/LH-0.6/1KV-XLPE (C)

    Conductor : Non-compacted and compacted round annealed copper
    Single-core Size 1.5 mm²  up to 630 mm²
    Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen
    Core identification : Signle-cores: Blank or Orange
    Fire barier tape : Mica tape
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 600/1000 Volts
    Related Voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502-1, IEC 60228, BS 6387 (Cat.CWZ),

      IEC 60332-1, IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2

    Read more
  • Placeholder

    FDLH-0.6/1KV-CE

    FDLH-0.6/1KV-CE

    Conductor : Non-compacted and compacted round annealed copper
    Single-core Size 1.5 mm²  up to 1000 mm²
    Insulation : Cross-Linked polyetylene (XLPE)
    Core identification

    : Single-crosss : Natural (Translucent)
    : 2 Cores : Blue, Brown
    : 3 Cores : Brown, Black, Gray
    : 4 Cores : Blue, Brown, Black, Gray

    Shield : Black Low smoke and zero halogen flame retardant polylefin (ST8)
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 1,200 Volts
    Related Voltage : 600 Volts between Line-to-Earth
    : 1,000 Volts between Line-to-Line
    Testing voltage : 3,500 Volts
    Reference standard

    : IEC 60502, IEC 60228, IEC 60332-1,

      IEC 60332-3-24 (Cat.C), IEC 60754-2, IEC 61034-2

    Read more
  • Placeholder

    FRLH-IE

    FRLH-IE

    Conductor : Non-compacted and compacted round annealed copper
    Size 1.5 mm²  up to 630 mm²
    Insulation : Cross-Linked polyetylene (XLPE) with Low smoke and Zero halogen
    Core identification : Single-crosss : Black or Orange
    Classification : Maximum concuctortemperature 90°C
    : Circuit voltage not exceeding 450/750 Volts
    Related Voltage : 45 Volts between Line-to-Earth
    : 75 Volts between Line-to-Line
    Testing voltage : 2,500 Volts
    Reference standard

    : BS EN 50525-3-41, BS EN 60228, BS EN 60332-1,

      BS EN 60332-3-24 (Cat.C), BS EN 50267-2-2, BS EN 61034-2

     

    Read more
  • CVV or CVV-S

    For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.

    Read more
  • 115 KV-CE

    For installation exposed, or in raceway, wet and dry location, or direct burial in ground.

    Read more
  • 69 KV-CE

    For installation exposed, or in raceway, wet and dry location, or direct burial in ground.

    Read more
  • 18/30(36) KV-CV

    18/30(36) KV-CV       : compact and round stranded annealed copper
                                    : 35 mm2 up to 1000 mm2 (Single Core)
                                    : 35 mm2 up to 400 mm2 (3 Cores)
                                    : Cross-linked Polyethylene (XLPE)
                                    : Black Polyvinyl Chloride (PVC/ST2)
                                    : Copper Tape (Shield)
                                    : Maximum conductor temperature 90 Degree C
                                    : Circuit voltage not exceeding 36000 V
    Insulation shield layer : Semi-conducting covering remove at splices or terminals
                                    : 63000 V (Testing Voltage)

    Read more
  • 6/10(12) KV-CV

    6/10(12) KV-CV          : Compact and round stranded annealed copper
                                     : 16 mm2 up to 1000 mm2 (Single Core)
                                     : 16 mm2 up to 400 mm2 (3 Cores)
                                     : Cross-linked Polyethylene (XLPE)
                                     : Black Polyvinyl Chloride (PVC/ST2)
                                     : Copper Tape (Sheath)
                                     : Maximum conductor temperature 90 Degree C
                                     : Circuit voltage not exceeding 12000 V
    Insulation shield layer  : Semi-conducting covering remove at splices or terminals
                                     : 21000 V (Testing Voltage)

    Read more